Руководство по распаковке AMS Combo и Laser Full Combo

Руководство по распаковке AMS Combo и Laser Full Combo

The packaging material and accessories may be updated from time to time. Please refer to the version you receive.

Please remove the new rear Z-axis foam during the unboxing process.
image

Video guide

The mapping relationship between AMS units and nozzles is one-to-one; filaments in a specific AMS unit can only be printed with the nozzle connected to that AMS unit.

For the unboxing guide of just the H2D, please click here.

Included items

AMS combo: H2D, AMS 2 Pro, and accessory box

image

Laser full combo: H2D, AMS 2 Pro, supply box, and accessory box

image

Laser Module Installation Guide

Cutting Module Installation Guide

Note: For the AMS Combo, the power cable is included with the AMS 2 Pro. For the Laser Full Combo, the power cable is located in the accessory box. Please refer to the H2D Packaging List.

Warning! If you will need to dry filament in more than one AMS 2 Pro at the same time with the H2D, you must use the official магазин Bambu Lab to power the additional AMS 2 Pro units. Using other power adapters may cause improper operation and could damage the equipment.

Procedures

Step 1. Remove the 4 box clip fasteners on the bottom.

image

Step 2. Lift and remove the outer box.

image
image

Step 3. Remove the 4 tapes on the bottom.

image

Step 4. Carefully read the quick start guide for detailed steps.

image

Step 5. Take out the supply box.

image

Step 6. Remove the foam pieces.

image
image
image

Step 7. Remove the air cushion.

image

Step 8. Tear open the stickers on both sides.

image
image

Step 9. Tear open the moisture-proof bag.

image

Step 10. Pull down and wrap the bag on the corners of the bottom cover.

image
image

Step 11. Two people lift and place the printer on a stable surface.

image
image
image

Step 12. Remove the packaging material on the printer.

image
image
image
image
image
image
image

Step 13. Take down the top cover.

image

Step 14. Take out the accessory box.

image
image

Note: The accessory box is for the Laser Full Combo.

Step 15. Remove the foam above the AMS 2 Pro.

image

Step 16. Remove the screws to unlock the AMS 2 Pro.

image

1. Remove the plastic part on the upper-left corner.

image
image
image

2. Remove the plastic part on the upper-right corner.

image
image
image

3. Remove the 2 screws on the fixture.

image
image

4. Take out the AMS 2 Pro.

image

Step 17. Remove the foam pieces.

image
image
image

Step 18. Remove the 4 screws and take out the fixture.

image
image

Step 19. Remove the 4 screws securing the heatbed.

image

Step 20. Remove the zip ties near the toolhead.

Do not cut the belt!

image
image
image
image

Step 21. Pull the toolhead towards the front door and remove the foam.

image

Step 22. Remove the foam pieces on the lead screws.

image
image
image
image

Step 23. Remove the tapes.

image
image

Step 24. Place the top cover on top of the printer.

image

Step 25. Remove the screw securing the air pump. (Only the laser version requires removing this screw; the non-laser version can skip this step.)

Loosen and slowly take the screw out to prevent it from falling inside the printer.

Please loosen the air pump screw before removing the silicone cap. The screw will be extracted along with the cap during this process.

To prevent the screw from falling into the back panel during removal, the silicone cap has been redesigned with a protruding structure. Do not pull off the cap before loosening the screw.

image

Step 26. Remove the protective film inside the AMS 2 Pro.

image

  • Accessories inside the AMS 2 Pro for the AMS combo:

image

  • Accessories inside the AMS 2 Pro for the laser full combo:

image

Step 27. Place the AMS 2 Pro on top of the printer.

image

Step 28. Insert one end of the PTFE tube in to the filament outlet of the AMS 2 Pro.

image

Step 29. Insert the other end into any coupler of the printer. Push until the tube cannot move forward. The tube is fully inserted if can be seen from the window on the buffer.

image
image

Note:
Due to the differences in the length of the tube in different batches and versions of the whole printer configuration, under the premise of ensuring that the loading resistance meets the requirements, appropriately shortening the length of the tube can effectively reduce the printing time.
After testing and verification, the length of the tube from the AMS to the H2D is recommended to be no less than 600mm to ensure the best working condition of the equipment.

Step 30. Insert the 6-pin cable into any port of the AMS 2 Pro and the other end into the printer.

image
image

Step 31. Take out the desiccant packs. Remove the packaging material and place them in the original place.

image
image
image

Step 32. Align the slot and slide the spool holder in place.

image
image

Step 33. Insert one end of the PTFE tube into the spool holder, and the other end to the other coupler of the printer. Push the tube until it cannot move forward. The tube is fully inserted if can be seen from the window on the buffer.

image
image
image

Step 34. Place a spool of filament on the spool holder. Insert and push the filament into the PTFE Tube until it cannot move forward.

image
image

Step 35. Take out the safety key on the back. Align and insert the safety key.

image
image
image

Step 36. Insert the power cord and switch on the printer.

image
image

Step 37. Follow the instructions to perform first calibration.

image
image
image

Step 38. After calibration completes, take out the foam pieces under the heatbed.

image
image

Step 39. Place a filament spool in the AMS 2 Pro. Push the feeder tab and insert filament so that the AMS 2 Pro can pre-load it.

image
image

When the LED light is on, the AMS 2 Pro is ready to print.

image

End Notes