Power Socket
The power socket assembly is a module located at the lower right rear side of the AMS HT.
When to Replace
- The power socket is damaged
- The power socket has poor contact
Required Tools and Materials
- New Power Socket
- H2.0 Hex Wrench
Safety Warning
IMPORTANT!
It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.
Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. По любым вопросам или сомнениям, связанным с этим руководством, мы рекомендуем отправить запрос в техподдержку.
Removing the Old Power Socket
1. Remove the PTFE Tube from AMS HT Back
Press the PTFE tube release button on the back of the AMS HT to unlock the connector, then pull out the PTFE tube.
2. Remove the Driven and Active Support Shaft
First, remove the Driven Support Shaft and Active Support Shaft from the material slot. Be careful with the bearings at both ends when removing the bearing sleeves.
image | image |
3. Remove the AMS HT Main Frame
Remove the two bottom screws (BT3×8).
Lift the main frame assembly slowly upward.
image | image |
After opening the gap, lift the main frame assembly. Note: Cables are connected—avoid forceful operation.
Unlock the connector latch and disconnect the front screen cable.
Next, disconnect the signal and power cables from the AMS HT Power Board.
image | image |
Remove the power socket-to-mainboard cable. Press the unlock latch and pull out the connector.
image | image |
4. Remove the Power Socket
Press the power socket latch and slide it backward to remove it along with the cable.
image | image |
Note: The power socket has elastic latches on both ends. Press both latches simultaneously to release it.
image
Installing the New Power Socket
1. Install the Power Socket
Route the AMS HT Power Socket Cable through the back of the AMS HT. Before securing the power socket, ensure the rubber gasket is properly inserted into the slot. Otherwise, the installation may result in looseness after completion.
Next, press the power switch socket into place until you hear a "click" sound, indicating it is securely installed.
2. Install the AMS HT Main Frame
Connect the two cables:
- Mainboard communication cable (14-pin).
- Mainboard power cable (2-pin).
Connect the power socket cable to the mainboard and reinstall the insulation sleeve.
Note: Polarity does not matter here.
Connect the front screen cable and secure it in the channel.
image | image |
Hook the protruding cables with your fingers and install the main frame into the bottom cover.
image | image |
Ensure the main frame is fully seated and secure it with two bottom screws (BT3×8).
image | image |
3. Install the Active and Driven Support Shafts
Press the Active Support Shaft into the front slot until it clicks. Align the black gear with the yellow gear inside the main frame.
Press the Driven Support Shaft into the main frame until it clicks.
Note: After installation, manually rotate the shafts to ensure smooth movement.
4. Insert the PTFE Tube into the AMS HT Back
Push the PTFE tube into the rear of the AMS HT. Pull it gently to confirm it is secure.
Device Calibration
Connect the power cable, attach the AMS HT to the printer, and turn on the power. From the printer’s display screen, start the AMS HT filament loading process.
If the filament loading completes successfully without any error messages, the replacement is complete.
If errors occur, please check all connections and try again.