Replace AMS HT Feeder Unit

Replace AMS HT Feeder Unit

AMS HT Feeder Unit

image

When to Use

  • Feeder unit is damaged
  • Recommended by Bambu Lab support

Required Tools and Materials

  • H2.0 Hex Wrench

  • H1.5 Hex Wrench

  • AMS HT Feeder Unit *1

  • Active Extrusion Wheel *1

  • 692ZZ Ball Bearing *1

  • BT2-8 Screw *4

image

Safety Warning

It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.
Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. По любым вопросам или сомнениям, связанным с этим руководством,

Removing the Old Feeder Unit

1. Remove the PTFE Tube from the Back of the AMS HT

Press the PTFE tube release button on the back of the AMS HT to unlock the connector, then pull out the PTFE tube.

image

2. Remove the AMS HT Main Frame

Remove the two bottom screws (BT3*8).

image

After removing the screws, slowly pull the main frame assembly upward.

image
image

Lift the main frame assembly upward after creating a gap, noting that cables are connected, so avoid forceful handling.

image

Unlock the connector latch and disconnect the front display cable.

image

Next, disconnect the signal and power cables from the AMS HT power board.

image
image

Remove the power socket to mainboard cable by pressing the unlock latch and pulling out the cable connector with the insulating rubber sleeve.

image
image

3. Remove the Feeder Unit

Remove the PTFE tube between the feeder unit and the outlet.

image

Remove the Hall (#3) connector and the feeder motor (#4) connector from the mainboard;

image

Remove the four fixing screws (BT2*8) of the feeder unit and take the feeder unit cable out of the cable management slot.

Replacing the feeder Unit does not require removing the mainboard.

image
image

Press the filament release button to push out the feeder unit.

image

4. Remove the Feeder Motor

Remove the two fixing screws (M2.5*8) of the feeder motor.

image
image

Remove the feeder motor and drive gear, ensuring the drive gear is preserved to avoid loss.

image
image

Installing the New Feeder Unit

1. Install the Feeder Motor

Install the drive gear onto the feeder motor.

image
image

Insert the motor into the feeder unit, ensuring the filament release button and motor cable are oriented in the same direction.

image
image

Secure the motor with the two fixing screws (M2.5*8).

image
image

2. Install the Feeder Unit

Install the feeder unit onto the main frame and secure it with the four fixing screws (BT2*8).

image

After installing the feeder unit, organize the cables into the cable management slot.

image
image

Insert the Hall cable and the feeder motor cable into mainboard #3 and #4 respectively;

image

Mainboard Connection Diagram

image

1. Filament Retraction Motor 2. Lid Status Hall Sensor 3. Odometer Board
4. 3520 AMS Internal Assist Motor 5. LCD Screen 6. Temperature & Humidity Sensor
7. Heating Unit Thermistor 8. Mainboard Power Connector 9. Feeder Hall Sensor Assembly
10. RFID Coil 11. Mainboard Communication Connector 12. Heating Unit Fan
13. Mainboard AC Input 14. Heating Unit AC Input

3. Install the AMS HT Main Frame

Connect the PTFE tube between the feeder and the outlet.

image

Connect the cables at positions 1 and 2, where position 1 is the mainboard communication cable (14-pin) and position 2 is the mainboard power cable (2-pin).

image

Connect the power socket cable to the mainboard and install the insulating rubber sleeve.

image

Note: The connection here does not distinguish between positive and negative poles.

Connect the AMS HT front display cable and ensure the cable is secured in the cable management slot.

image
image

Hook the protruding cable with your finger and install the mid-frame assembly into the bottom shell assembly.

image
image

Ensure the main frame assembly is fully pressed into the bottom shell assembly without any front or rear tilting, and secure it with the two bottom fixing screws (BT3*8).

image
image

4. Insert the PTFE Tube into the Back of the AMS HT

Push the PTFE tube into the back of the AMS HT. After installation, tug the PTFE tube to confirm it is securely fixed.

image

Verify the functionality

After replacement, connect the AMS HT to the printer. Load filament and test the load and unload functions. If both functions operate without issues, the replacement is successful.

image

End Notes