Замена нагревательного блока AMS 2 Pro

Замена нагревательного блока AMS 2 Pro

Applicable models

AMS 2 Pro (Hereinafter referred to as AMS)

This article takes one of the heating units (slots 1 and 2) as an example. The disassembly and assembly methods of the other heating unit is exactly the same.

AMS 2 Pro heating unit

The AMS heating unit is a component for drying filaments inside the AMS, consisting of a heater, a fan, and an NTC temperature sensor.
Heater 1 (left side): Supplies slots 1-2,visible by fan sticker
Heater 2 (right side): Supplies slots 3-4,visible by fan blades

image

image

When to use?

The filament is dried abnormally, and an HMS error message appears, indicating that the module needs to be replaced, or the after-sales technical support team determines that the module needs to be replaced after diagnosing the fault.

Tools and materials needed

  • New AMS 2 Pro Heating Unit

  • H2.0 Allen key

  • H1.5 Allen key

  • 20 minutes

Screws List

Safety Warning

IMPORTANT!

It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.

During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.

Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. По любым вопросам или сомнениям, связанным с этим руководством, мы рекомендуем отправить запрос в техподдержку.

Before starting, make sure the AMS is disconnected from the printer.

Remove the heating unit

Step 1 - Remove the PTFE tube on the back of the AMS

Press the PTFE tube release button from the back of the AMS to unlock the fitting, then pull the PTFE tube out from the back of the AMS.

image

Step 2 - Pull out the PTFE tube release button

Pinch the clip from the inside of the lower cover to automatically pop open the PTFE tube release button, and then pull out the PTFE tube release button from the back of the AMS.

image

image

When squeezing the buckle, use your other hand to hold the PTFE tube from the back of the AMS to release the switch to prevent the spring from being ejected and lost.

Step 3 - Remove the AMS main frame assembly

Remove the driven support sleeve assembly of the two middle slots to expose the two screw holes. When removing the bearing sleeve, be careful with the bearings at both ends to avoid losing them.

image

image

Remove the two screws A that secure the AMS main frame.

image

image

Lift the rear part of the main frame completely and place it vertically on the lower cover of the AMS. Note that there are cables connected, so do not operate violently. When lifting, it is recommended to lift the front part of the main frame first, and then push it forward to make room for the rear part of the frame.

When placing the AMS main frame vertically, avoid the electronic components of the vent to prevent them from being crushed.

image

image

Unlock the plug buckle, unplug the signal cable and power cable on the AMS power board, and lift out the AMS main frame assembly as a whole.

image

image

Step 4 - Disconnect cables and remove screws

Unplug the 3 plugs of the heating unit heater, fan and NTC from the connector on the mainboard, remove the cables from the clips, and remove the 4 screws.

image

image

Step 5 - Remove the heating unit

The heating unit is fixed by 4 screws and 2 clips. After removing the 4 screws, use a tool to gently pry the plastic frame near the buckle to unlock the buckle. It is recommended to pry open the buckle near the RFID coil first. After prying it open, hold the heating unit with your hand, then pry up the other clip, and finally remove the heating unit.

image

image

Install the heating unit

Step 1 - Install the heating unit

Install the heating unit onto the AMS main frame, align the 4 screw holes, and press down slightly to insert the left and right clips into the side walls of the frame. When installed in place, you can hear a slight "click" sound.

image

image

Step 2 - Connect cables and tighten screws

Connect the 3 plugs of the heating unit heater, fan and NTC to the connector on the mainboard, arrange the cables, and tighten the 4 screws.

image

Step 3 - Install the main frame assembly and driven support sleeve assembly

Install the AMS main frame assembly into the AMS lower cover and connect the signal cable and power cable to the AMS power board.

image

image

Make sure the bottom clip on the front of the main frame is aligned with the clip on the bottom cover unit, and then insert and install.

image

After the AMS main frame is installed in place, tighten the two screws to secure it.

image

Install the two middle driven support sleeve assemblies, making sure that the bearings on both ends of all support shafts are pressed into place.

image

image

Step 4 - Install the PTFE tube release button

Press the PTFE tube release button back into the housing in the following direction, insert the buckle into the corresponding slot smoothly, and keep the black silicone housing embedded flat.

image

image

image

Step 5 - Connect the PTFE tube

Check to make sure that the PTFE tube silicone bracket is aligned with the filament hole of the filament hub unit, and push the PTFE tube from the rear of the AMS. After installation, pull the PTFE tube to confirm that the PTFE tube is fixed.

image

image

Calibration

Connect the power cable, connect the AMS to the printer, turn on the power, and start using the AMS to load filaments through the operation on the screen. If the loading can be completed and no error prompts appear during the entire loading process, the replacement is successful.

Otherwise, please check all connections and try again. If the problem persists, please обратитесь в сервисную команду Bambu Lab для получения дальнейшей помощи.

End Notes